Renesas Computer Hardware H8 3627 Series User Guide

H8/3627 Series QFP-64E  
User System Interface Cable  
(HS3627ECN61H)  
for E6000 Emulator  
User’s Manual  
HS3627ECN61HE(C)  
 
Preface  
Thank you for purchasing this user system interface cable (HS3627ECN61H) for the Renesas’s  
original microcomputer H8/3627 series.  
The HS3627ECN61H is a user system interface cable that connects an H8/300L series E6000  
emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-64E  
package (package code: FP-64E) for the H8/3627 series MCU on the user system.  
i
 
Contents  
ii  
 
Section 1 Configuration  
CAUTION  
Use an IC149-064-075-B51 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E  
package IC socket on the user system.  
Figure 1 shows the configuration of the HS3627ECN61H user system interface cable for the  
FP-64E package.  
1
 
 
To emulator station  
Cable body  
Screws (M2 x 12 mm)  
with flat washers  
(for fastening cable head)  
Screws (M2 x 6 mm)  
with flat washers  
Socket cover  
Cable head  
IC socket  
User system  
Figure 1 HS3627ECN61H User System Interface Cable  
2
 
Table 1 lists the HS3627ECN61H components. Please make sure you have all of these components  
when unpacking.  
Table 1  
HS3627ECN61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
5
6
Cable body  
1
1
1
1
4
4
Includes flat cable  
Cable head  
IC socket  
For the FP-64E package  
Socket cover  
For installing an FP-64E-packaged MCU  
For fastening cable head (with four flat washers)  
Screws (M2 x 12 mm)  
Screws (M2 x 6 mm)  
For installing an FP-64E-packaged MCU (with four  
flat washers)  
7
Documentation  
1
User’s manual for HS3627ECN61H (this manual)  
3
 
Section 2 Connection Procedures  
Connecting User System Interface Cable to Emulator Station  
WARNING  
2.1  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before connecting,  
make sure that pin 1 on both sides are correctly aligned. Failure to  
do so will damage the user system and the emulator product or will  
result in PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
Emulator station  
0
0
0
6
E
Cable body  
User system interface cable  
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
 
 
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before connecting,  
make sure that pin 1 on both sides are correctly aligned. Failure to  
do so will damage the user system and the emulator product or will  
result in PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of  
the IC socket for an FP-64E package, and fasten it to the user system before soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-64E package to the user system. Be sure to  
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system  
interface cable head, and insert the user system interface cable head into the IC socket on the user  
system, as shown in figure 3.  
5
 
 
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Phillips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.13 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be caused  
by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
6
 
 
Fasten the user system interface cable head to the IC socket for an FP-64E package on the user  
system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw should be  
tightened a little at a time, alternating between screws on opposing corners. Take special care, such  
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being  
damaged by overtightening the screws or twisting the components.  
Figure 3 Connecting User System Interface Cable to User System  
7
 
2.2.5  
Connecting Cable Body to Cable Head  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jig  
Remove jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
 
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an FP-64E package (IC149-064-075-B51: manufactured by YAMAICHI  
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those  
of the actual chip's mount pad.  
Unit: mm  
Figure 5 Recommended Dimensions for Mount Pad  
9
 
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
Unit: mm  
Tolerance: –0.5 mm  
Figure 6 Dimensions for User System Interface Cable Head  
10  
 
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
 
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Phillips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.29 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be caused  
by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws  
(M2 x 6 mm; with four flat washers). Take special care, such as manually securing the IC socket  
soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting  
the components.  
12  
 
 
Figure 8 Installing MCU to User System  
13  
 
Section 4 Verifying Operation  
1. When using the H8/300L series E6000 emulator (HS3L08EPI60H), turn on the emulator  
according to the procedures described in the H8/300L Series E6000 Emulator User's Manual  
(HS3008EPI60HE).  
2. Verify the user system interface cable connections by accessing ports and checking the bus  
states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin  
1.  
3. The emulator connected to this user system interface cable supports two kinds of clock sources:  
an emulator internal clock and an external clock on the user system, for the MCU clock and  
subclock. For details, refer to the H8/300L Series E6000 Emulator User's Manual  
(HS3008EPI60HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ) and the subclock  
(φw), by using the CLOCK command (emulator command).  
To use the external clock on the user system as the system clock  
Select target clock t2 with the CLOCK command (emulator command). Supply the external  
clock from the user system to the emulator. When a crystal oscillator is inserted into the  
OSC1 and OSC2 terminals for the system clock, the clock is generated by the oscillator  
circuits shown in figure 9. To input an external clock from the user system, input clock  
pulses satisfying the specifications described in the MCU hardware manual into the OSC1  
terminal. The system clock (φ) frequency is half of the external clock frequency.  
To use the external clock on the user system as the subclock  
Select target clock sub t with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator. To input an external subclock from the  
user system, input clock pulses satisfying the specifications shown in figure 9 into the X1  
terminal. The oscillator circuits on the user system interface cable cannot generate external  
subclock pulses by using the crystal oscillator connected to the user system.  
14  
 
 
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input  
specifications.  
R1 1 M Ω  
Vcc  
0.8 Vcc  
0.8 Vcc  
HCU04  
To E6000  
emulator  
HCU04  
0.3 Vcc  
0.3 Vcc  
R2 270Ω  
55 ns max. 55 ns max.  
0 V  
OSC1 OSC2  
Vcc: User System Vcc  
(3.0 V to 5.0 V)  
System clock oscillator  
Subclock input specifications  
Figure 9 System Clock Oscillator and Subclock Input Specifications  
15  
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different from  
those of the MCU.  
3. This user system interface cable is specifically designed for the HS3L08EPI60H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 10.  
Place components so that the cable body  
and cable head are parallel to the  
Cable  
user system.  
Emulator station  
Cable head is parallel  
to emulator station  
Cable head is parallel  
to user system  
User system  
Figure 10 User System Interface Cable Location Example  
6. The P1 short connector is used for testing. Do not remove the short pins that are inserted in the  
sides of pin 1 and pin 2.  
3
1
P1  
Figure 11 P1 Short Connector  
16  
 
 

Raymarine GPS Receiver VolvoPenta IPS Autopilot System DPU User Guide
RCA MP3 Player SL5004 User Guide
Roberts Radio Clock Radio CR9951 User Guide
Roland Electronic Keyboard PK 7A User Guide
Roland Engraver EGX 350 User Guide
Rose electronic Switch Automatic Switch User Guide
Samsung Digital Camera TL500 User Guide
Sanyo Projector Accessories LNS T02K User Guide
Sears Lawn Mower 917255741 User Guide
Sears TV DVD Combo SRCD223 User Guide