H8/3627 Series QFP-64E
User System Interface Cable
(HS3627ECN61H)
for E6000 Emulator
User’s Manual
HS3627ECN61HE(C)
Preface
Thank you for purchasing this user system interface cable (HS3627ECN61H) for the Renesas’s
original microcomputer H8/3627 series.
The HS3627ECN61H is a user system interface cable that connects an H8/300L series E6000
emulator (HS3L08EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-64E
package (package code: FP-64E) for the H8/3627 series MCU on the user system.
i
Contents
Section 1 Configuration....................................................................................1
Section 2 Connection Procedures......................................................................4
2.1 Connecting User System Interface Cable to Emulator Station .........................................4
2.2 Connecting User System Interface Cable to User System ................................................5
2.2.1 Installing IC Socket .............................................................................................5
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................5
2.2.4 Fastening Cable Head ..........................................................................................6
2.2.5 Connecting Cable Body to Cable Head ...............................................................8
2.3 Recommended Dimensions for User System Mount Pad .................................................9
2.4 Dimensions for User System Interface Cable Head..........................................................10
2.5 Resulting Dimensions after Connecting User System Interface Cable.............................11
Section 4 Verifying Operation...........................................................................14
Section 5 Notice ................................................................................................16
ii
To emulator station
Cable body
Screws (M2 x 12 mm)
with flat washers
(for fastening cable head)
Screws (M2 x 6 mm)
with flat washers
Socket cover
Cable head
IC socket
User system
Figure 1 HS3627ECN61H User System Interface Cable
2
Table 1 lists the HS3627ECN61H components. Please make sure you have all of these components
when unpacking.
Table 1
HS3627ECN61H Components
No. Component
Quantity
Remarks
1
2
3
4
5
6
Cable body
1
1
1
1
4
4
Includes flat cable
Cable head
IC socket
For the FP-64E package
Socket cover
For installing an FP-64E-packaged MCU
For fastening cable head (with four flat washers)
Screws (M2 x 12 mm)
Screws (M2 x 6 mm)
For installing an FP-64E-packaged MCU (with four
flat washers)
7
Documentation
1
User’s manual for HS3627ECN61H (this manual)
3
Section 2 Connection Procedures
Connecting User System Interface Cable to Emulator Station
WARNING
2.1
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before connecting,
make sure that pin 1 on both sides are correctly aligned. Failure to
do so will damage the user system and the emulator product or will
result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
To connect the cable body to the emulator station, follow the instructions below.
1. Make sure the user system and emulator station are turned off.
2. After making sure the direction of the cable body connector is correct, firmly insert the cable
body connector into the emulator station socket (figure 2).
Emulator station
0
0
0
6
E
Cable body
User system interface cable
Figure 2 Connecting User System Interface Cable to Emulator Station
4
2.2
Connecting User System Interface Cable to User System
WARNING
Always switch OFF the user system and the emulator
product before the USER SYSTEM INTERFACE CABLE
is connected to or removed from any part. Before connecting,
make sure that pin 1 on both sides are correctly aligned. Failure to
do so will damage the user system and the emulator product or will
result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
To connect the cable head to the user system, follow the instructions below.
2.2.1 Installing IC Socket
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of
the IC socket for an FP-64E package, and fasten it to the user system before soldering.
2.2.2
Soldering IC Socket
After fastening, solder the IC socket for an FP-64E package to the user system. Be sure to
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
(Use slightly more solder than the MCU.)
2.2.3
Inserting Cable Head
CAUTION
Check the location of pin 1 before inserting.
Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system
interface cable head, and insert the user system interface cable head into the IC socket on the user
system, as shown in figure 3.
5
2.2.4
Fastening Cable Head
CAUTION
1. Use a Phillips-type screwdriver whose head matches
the screw head.
2. The tightening torque must be 0.13 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be caused
by a crack in the IC socket solder.
3. If the emulator does not operate correctly, cracks might
have occurred in the solder. Check conduction with
a tester and re-solder the IC socket if necessary.
6
Fasten the user system interface cable head to the IC socket for an FP-64E package on the user
system with the four screws (M2 x 12 mm; with four flat washers) provided. Each screw should be
tightened a little at a time, alternating between screws on opposing corners. Take special care, such
as manually securing the IC socket soldered area, to prevent the soldered IC socket from being
damaged by overtightening the screws or twisting the components.
Figure 3 Connecting User System Interface Cable to User System
7
2.3
Recommended Dimensions for User System Mount Pad
Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with
an IC socket for an FP-64E package (IC149-064-075-B51: manufactured by YAMAICHI
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those
of the actual chip's mount pad.
Unit: mm
Figure 5 Recommended Dimensions for Mount Pad
9
Section 3 Installing the MCU to the User System
CAUTION
1. Check the location of pin 1 before inserting.
2. Use a Phillips-type screwdriver whose head matches
the screw head.
3. The tightening torque must be 0.29 N•m or less.
If the applied torque cannot be accurately measured,
stop tightening when the force required to turn the screw
becomes significantly greater than that needed when first
tightening. If a screw is tightened too much, the screw
head may break or an IC socket contact error may be caused
by a crack in the IC socket solder.
4. If the MCU does not operate correctly, cracks might have
occurred in the solder. Check conduction with a tester
and re-solder the IC socket if necessary.
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four screws
(M2 x 6 mm; with four flat washers). Take special care, such as manually securing the IC socket
soldered area, to prevent the IC socket from being damaged by overtightening the screws or twisting
the components.
12
Figure 8 Installing MCU to User System
13
Section 4 Verifying Operation
1. When using the H8/300L series E6000 emulator (HS3L08EPI60H), turn on the emulator
according to the procedures described in the H8/300L Series E6000 Emulator User's Manual
(HS3008EPI60HE).
2. Verify the user system interface cable connections by accessing ports and checking the bus
states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin
1.
3. The emulator connected to this user system interface cable supports two kinds of clock sources:
an emulator internal clock and an external clock on the user system, for the MCU clock and
subclock. For details, refer to the H8/300L Series E6000 Emulator User's Manual
(HS3008EPI60HE).
To use the emulator internal clock
Select the clock in the emulator station as the system clock (φ) and the subclock
(φw), by using the CLOCK command (emulator command).
To use the external clock on the user system as the system clock
Select target clock t2 with the CLOCK command (emulator command). Supply the external
clock from the user system to the emulator. When a crystal oscillator is inserted into the
OSC1 and OSC2 terminals for the system clock, the clock is generated by the oscillator
circuits shown in figure 9. To input an external clock from the user system, input clock
pulses satisfying the specifications described in the MCU hardware manual into the OSC1
terminal. The system clock (φ) frequency is half of the external clock frequency.
To use the external clock on the user system as the subclock
Select target clock sub t with the CLOCK command (emulator command). Supply the
external clock from the user system to the emulator. To input an external subclock from the
user system, input clock pulses satisfying the specifications shown in figure 9 into the X1
terminal. The oscillator circuits on the user system interface cable cannot generate external
subclock pulses by using the crystal oscillator connected to the user system.
14
Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input
specifications.
R1 1 M Ω
Vcc
0.8 Vcc
0.8 Vcc
HCU04
To E6000
emulator
HCU04
0.3 Vcc
0.3 Vcc
R2 270Ω
55 ns max. 55 ns max.
0 V
OSC1 OSC2
Vcc: User System Vcc
(3.0 V to 5.0 V)
System clock oscillator
Subclock input specifications
Figure 9 System Clock Oscillator and Subclock Input Specifications
15
Section 5 Notice
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable
head before inserting the cable head into the user system IC socket.
2. The dimensions of the recommended mount pad for the user system IC socket are different from
those of the MCU.
3. This user system interface cable is specifically designed for the HS3L08EPI60H emulator. Do
not use this cable with any other emulator station.
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the
user system interface cable.
5. While the emulator station is connected to the user system with the user system interface cable,
force must not be applied to the cable head. Place the emulator station, user system interface
cable, and user system as shown in the example in figure 10.
Place components so that the cable body
and cable head are parallel to the
Cable
user system.
Emulator station
Cable head is parallel
to emulator station
Cable head is parallel
to user system
User system
Figure 10 User System Interface Cable Location Example
6. The P1 short connector is used for testing. Do not remove the short pins that are inserted in the
sides of pin 1 and pin 2.
3
1
P1
Figure 11 P1 Short Connector
16
|